Thanks to the dose monitoring and DICOM functionalities, a report of the individual exposures (or of the entire examination) is generated, thus allowing a possible export of the data in DICOM format to a network node. Detected dose values are displayed on the X-FRAME DR/DRF dose monitoring and automatically stored in the DICOM file. Thanks to the DICOM MPPS, all details related to patient exposure are saved together with the image, in a standard format and can be sent automatically or on request, to a dose analysis system (Radiation Report System) and / or to RIS-PACS. Dose monitoring

Improve patient care also for babies

Anatomical Programs and pediatric applications

Italray systems offer dedicated packages for Paediatrics and Neonatology. Acquisition and Processing Protocols are organized according to programmable anatomical tables, optimized for specific projections and / or incidences and are differentiated according to different ages of the paediatric patient.

Dose measurement and reporting

High DQE

High sensitivity digital detectors with high DQE for a significant dose reduction compared to conventional systems

Dose reduction 

Improve patient care also for children

Anatomical Programs and pediatric applications

Italray systems offer dedicated packages for Paediatrics and Neonatology. Acquisition and Processing Protocols are organized according to programmable anatomical tables, optimized for specific projections and / or incidences and are differentiated according to different ages of the paediatric patient.

Dose measurement and reporting

Thanks to the dose meter (DAP) and DICOM functionalities, a report of the individual exposures (or of the entire examination) is generated, thus allowing a possible export of the data in DICOM format to a network node. Detected dose values are displayed on the X-FRAME DR/DRF monitor and automatically stored in the DICOM file. Thanks to the DICOM MPPS, all details related to patient exposure are saved together with the image, in a standard format and can be sent automatically or on request, to a dose analysis system (Radiation Report System) and / or to RIS-PACS.

High DQE

High sensitivity digital detectors with high DQE for a significant dose reduction compared to conventional systems

OPERATIVE FLEXIBILITY

Maximum operational flexibility with wireless detector that can be shared with all Italray systems

OPERATIVE FLEXIBILITY 

QUALITY IN IMAGE PROCESSING

with everest-x hierarchical algorithm

QUALITY IN IMAGE PROCESSING

DOSE REDUCTION

dose reduction systems for both patients and operators

DOSE REDUCTION

DICOM 3.0 SYSTEM

Worklist, exam, reporting for image data immediate availability

DICOM 3.0 SYSTEM